Precision Acrylic Packed Column
50.0 mm inner diameter column with 500 mm active bed length and calibrated support grid.
Measure laminar liquid pressure drop across a column packed with random Raschig rings/spherical packing, verify the Kozeny–Carman equation, and evaluate packed bed permeability K. Explore interactive transport phenomena, unit operations simulation, and chemical engineering telemetry.
Ready to sample with Velocity u_0 = 3.0 mm/s.
Adjust Velocity u_0, then execute chemical process trial.
Chemical and process engineering telemetry is evaluated rigorously using 64-bit IEEE 754 precision. Residuals reflect ordinary least-squares regression across successive observations. Continuous data structures support high-fidelity transport phenomena and unit operations modeling.
The transport and thermodynamic models apply within the specified calibrated operating window (1.0 to 6.0 mm/s). Evaluated using a 50.0 mm ID column packed with 6.0 mm borosilicate glass Raschig rings (voidage ε = 0.58) over a bed length L = 500 mm. Linear regression relates pressure drop ΔP directly to superficial liquid velocity u_0.
50.0 mm inner diameter column with 500 mm active bed length and calibrated support grid.
6.0 mm random packing providing reproducible void fraction ε = 0.58 and high specific surface area.
Delivers pulsation-damped, laminar liquid flow from 0.5 to 8.0 mm/s.
Measures pressure drop across bed end taps from 0 to 20 kPa with 0.02 kPa accuracy.
Gravimetrically verifies volumetric discharge rate to calibrate superficial velocity u_0.
Maintains percolating liquid at 20.0 ± 0.1 °C to ensure constant dynamic viscosity.
Measure laminar liquid pressure drop across a column packed with random Raschig rings/spherical packing, verify the Kozeny–Carman equation, and evaluate packed bed permeability K. Standardized parameter settings: 1.0, 2.0, 3.0, 4.0, 5.0, 6.0 mm/s.
Pack the column with Raschig rings under water to prevent air pocket entrapment; circulate degassed water at low flow to displace all micro-bubbles.
Halt flow and verify that the differential pressure transmitter reads exactly 0.000 kPa across the 500 mm bed taps.
Set pump delivery to achieve superficial velocity u_0 = 1.0 mm/s; allow pressure to steady for 120 seconds and log differential pressure ΔP.
Increase superficial velocity in uniform steps through 2.0, 3.0, 4.0, 5.0, and 6.0 mm/s, recording steady-state differential pressure at each plateau.
Collect effluent for 120 seconds into a tared vessel at each plateau to confirm volumetric throughput and exact superficial velocity.
Plot bed pressure drop ΔP versus superficial velocity u_0, extract the resistance slope S, and compute the bed permeability K.
Points are your recorded observations. The solid regression line validates Packed Bed Permeability mathematical scaling.
| # | Superficial Liquid Velocity u_0 (mm/s) | Packed Bed Pressure Drop ΔP (kPa) | Superficial liquid velocity u_0 (mm/s) | Packed bed pressure drop ΔP (kPa) | Remove |
|---|
No readings yet. Execute a process trial and record it.
Packed bed columns are fundamental contactors across absorption, distillation, heterogeneous catalysis, groundwater filtration, and chromatography. When liquid percolates through a stationary porous medium packed with random packing elements (such as Raschig rings, Berl saddles, or glass spheres), the interstitial flow pathways form a complex network of tortuous, interconnected micro-channels. At low pore Reynolds numbers (Re_p < 2), viscous shear dissipation dominates momentum transport, and flow obeys Darcy's macroscopic filtration law: u_0 = (K / μ) · (ΔP / L). The classic Kozeny–Carman model derives this empirical relationship mechanistically by idealizing the interstitial pore space as a bundle of parallel tortuous capillary conduits of hydraulic radius R_h = ε / [a_v · (1 - ε)], where ε is bed voidage and a_v is specific surface area per unit volume of solid particles. Substituting into the Hagen–Poiseuille capillary equation yields the Kozeny–Carman equation: ΔP / L = [k_K · μ · a_v^2 · (1 - ε)^2 / ε^3] · u_0, where k_K ≈ 5.0 is the empirical Kozeny constant. In this laboratory experiment, water is pumped at controlled superficial velocities through a 500 mm packed column to verify linear Darcy scaling, quantify the hydraulic resistance slope S, and evaluate the specific permeability K.
Evaluated using a 50.0 mm ID column packed with 6.0 mm borosilicate glass Raschig rings (voidage ε = 0.58) over a bed length L = 500 mm. Linear regression relates pressure drop ΔP directly to superficial liquid velocity u_0.