Chemistry / Persulfate-Iodide Clock Kinetics
FREE TO EXPLORE
LABORATORY 21 · NATURAL SCIENCES

Chemical Kinetics of the Persulfate-Iodide Clock Reaction

To determine the reaction order with respect to peroxodisulfate (S₂O₈²⁻), evaluate the pseudo-first-order rate constant (k') and the second-order rate constant (k) for the oxidation of iodide by persulfate at 25.0 °C and constant ionic strength (I = 0.20 M) using the initial rates iodine clock method with spectrophotometric and visual monitoring, and verify the activated complex ionic strength dependence. Explore interactive analytical gravimetry, Class A volumetric glassware and density determination.

MEASURE · CALIBRATE · ANALYSE

Your virtual chemistry laboratory.

CLOCK TIME TO SUDDEN BLUE COLOR CHANGE ΔT—
MEASUREMENT STATUS

Ready to dispense 30.0 mM of liquid.

30.0 mM
Optically shielded reaction cell with water jacket maintained at 25.00 ± 0.02 °C and integrated magnetic stirrer (400 rpm).

Adjust persulfate concentration V, then weigh the dispensed aliquot.

Mass observations are determined by the high-precision thermodynamic equation of state for pure liquid water. Readings reflect thermal equilibrium and analytical balance force restoration.

Physical chemistry assumptions and metrological limits

The simple bimolecular rate law r = k·[S₂O₈²⁻]·[I⁻] assumes that ionic strength is held constant and that reactant concentrations are low enough (< 0.1 M) for Debye-Hückel screening to apply. At very high ionic strength (I > 1.0 M), specific ion interaction parameters and ion-pairing (e.g., K⁺·S₂O₈²⁻) produce non-linear deviations from the Brønsted-Bjerrum equation. The physical simulation model computes the persulfate-iodide oxidation rate at 25.00 °C and ionic strength I = 0.20 M governed by r₀ = −d[S₂O₈²⁻]/dt = k·[S₂O₈²⁻]₀·[I⁻]₀, where the true second-order rate constant is k = 0.02200 L·mol⁻¹·s⁻¹. Fixed experimental conditions: excess iodide [I⁻]₀ = 0.0800 M and limiting thiosulfate Δ[S₂O₃²⁻]₀ = 0.00100 M. Under constant iodide, the reaction behaves with pseudo-first-order kinetics: r₀ = k'·[S₂O₈²⁻]₀ with k' = k·[I⁻]₀ = 0.02200 × 0.0800 = 0.001760 s⁻¹. The clock time to the sharp starch-triiodide flash transition satisfies Δt = Δ[S₂O₃²⁻]₀ / (2·r₀) = 0.000500 / r₀. For initial persulfate concentrations [S₂O₈²⁻]₀ from 10.0 mM to 60.0 mM (0.010 M to 0.060 M), initial rates span 1.760 × 10⁻⁵ M/s (Δt = 28.409 s) to 1.056 × 10⁻⁴ M/s (Δt = 4.735 s). Linear regression of r₀ × 10⁵ against [S₂O₈²⁻]₀ (in mM) yields slope m = 0.1760 (10⁻² s⁻¹), isolating k' = 0.001760 s⁻¹ and k = k' / [I⁻]₀ = 0.0220 L·mol⁻¹·s⁻¹ with R² = 1.00000; the multi-point initial rates formulation completely eliminates product inhibition and reverse reaction biases.

Analytical chemistry apparatus & tools.

Water-Jacketed Optical Reaction Vessel

Optically clear cylindrical borosilicate cell surrounded by a circulating thermal jacket (25.00 ± 0.02 °C) equipped with PTFE magnetic stir bar for rapid, homogeneous reagent mixing.

Photodiode Optical Detector & Microsecond Timer

Collimated LED light source and high-speed silicon photodetector that continuously monitors transmission and triggers a digital timer the millisecond optical absorbance surges at the starch-iodine endpoint.

Class A Volumetric Pipettes (5.00 to 25.00 mL)

Precision calibrated volumetric glassware used to dispense exact aliquots of stock persulfate, iodide, thiosulfate, starch, and ionic strength compensating salts.

Circulating Thermostatic Water Bath

Constant-temperature bath maintaining reagents and the reaction vessel strictly at 25.00 ± 0.02 °C to eliminate temperature-induced Arrhenius rate fluctuations.

Magnetic Stirrer Controller (Digital RPM)

Microprocessor-controlled magnetic drive maintaining an invariant vortex speed of 400 ± 5 rpm to ensure instantaneous reagent dispersal without air bubble entrainment.

High-Purity Reagents: K₂S₂O₈, KI, Na₂S₂O₃, & Soluble Starch

Analytical grade potassium persulfate (oxidant), potassium iodide (reductant), standardized sodium thiosulfate (clock scavenger), and 1.0% soluble starch indicator solution.

FOLLOW THE METHOD

A reason behind every step.

To determine the reaction order with respect to peroxodisulfate (S₂O₈²⁻), evaluate the pseudo-first-order rate constant (k') and the second-order rate constant (k) for the oxidation of iodide by persulfate at 25.0 °C and constant ionic strength (I = 0.20 M) using the initial rates iodine clock method with spectrophotometric and visual monitoring, and verify the activated complex ionic strength dependence. Suggested independent volumetric settings: 10.0, 20.0, 30.0, 40.0, 50.0, 60.0 mM.

01

Stock Reagent Preparation and Temperature Equilibration

Prepare fresh stock solutions of 0.100 M K₂S₂O₈, 0.200 M KI, 0.0100 M Na₂S₂O₃, and 0.200 M KNO₃. Immerse all volumetric flasks in the 25.00 °C thermostatic water bath for 30 minutes to achieve thermal equilibrium.

02

Formulation of the Iodide-Thiosulfate-Starch Cocktail (Flask A)

Into Flask A, accurately pipette 20.00 mL of 0.200 M KI (yielding [I⁻] = 0.0800 M in 50 mL final volume), 5.00 mL of 0.0100 M Na₂S₂O₃, 2.00 mL of 1.0% starch indicator, and appropriate volumes of KNO₃ to maintain ionic strength at I = 0.200 M.

03

Preparation of the Variable Persulfate Solution (Flask B)

Into Flask B, pipette the calculated volume of 0.100 M K₂S₂O₈ corresponding to the desired initial concentration (5.00 mL for 10.0 mM, up to 30.00 mL for 60.0 mM), adding (NH₄)₂SO₄ as necessary to hold sulfate ionic strength constant, and dilute with water to 25.00 mL.

04

Rapid Mixing and Automatic Timing Initiation

Transfer Flask A into the water-jacketed reaction cell on the magnetic stirrer (400 rpm). Swiftly pour the contents of Flask B into the cell, instantaneously starting the automated photodiode stopwatch at the moment of mixing (t = 0).

05

Monitoring and Sudden Starch-Iodine Flash Endpoint Capture

Observe the crystal-clear reaction mixture. Maintain continuous agitation until the solution transitions instantaneously from completely colorless to an opaque, deep blue-black; the photodiode circuit detects the sudden drop in optical transmittance and halts the timer at Δt.

06

Repetition Across Concentration Series and Rate Constant Modeling

Repeat duplicate trials for [S₂O₈²⁻]₀ = 10.0, 20.0, 30.0, 40.0, 50.0, and 60.0 mM, compute initial rates r₀ = Δ[S₂O₃²⁻]₀ / (2·Δt), plot r₀ against [S₂O₈²⁻]₀, and perform linear regression to determine reaction orders and rate constants.

YOUR NOTEBOOK · 0 OBSERVATIONS

Turn measurements into quantitative chemical insight.

See a complete example report ↗

Points are your recorded gravimetric observations. The regression line validates the linear mass-volume proportionality and extracts density.

ORDINARY LEAST-SQUARES FIT · m = ρ·V + m₀
r_0 = k' \cdot [\text{S}_2\text{O}_8^{2-}]_0 ==> r_0 \times 10^5 = 0.1760 \cdot [\text{S}_2\text{O}_8^{2-}]_0
#Initial persulfate concentration [S₂O₈²⁻]₀ (mM) (mM)Clock time to sudden blue color change Δt (s)Initial persulfate concentration [S₂O₈²⁻]₀ (mM)Initial reaction rate r₀ (10⁻⁵ mol·L⁻¹·s⁻¹)Remove

No readings yet. Dispense and weigh a volumetric aliquot to record it.

Calculate it yourself.

CHECK YOUR UNDERSTANDING

Explain what the gravimetric measurements mean.

In the persulfate-iodide clock reaction, what is the role of sodium thiosulfate (Na₂S₂O₃)?

Why does the persulfate-iodide reaction exhibit a positive primary kinetic salt effect (rate constant k increases with increasing ionic strength)?

If initial persulfate concentration is doubled from 20.0 mM to 40.0 mM while excess iodide remains constant, what happens to the clock time Δt?

Given pseudo-first-order rate constant k' = 0.001760 s⁻¹ at [I⁻]₀ = 0.0800 M, what is the second-order rate constant k?