Civil Engineering / Casagrande Liquid Limit
FREE TO EXPLORE
LABORATORY 25 · CIVIL ENGINEERING

Casagrande Liquid Limit lab report

A worked casagrande liquid limit lab report with sample observation tables, regression plots, calculations, and error analysis.

WORKED EXAMPLE · BENCHMARK OBSERVATIONS

A complete example civil engineering laboratory report.

Simulated demonstration data.

This report illustrates formal civil engineering data reduction, instrument calibration tares, and structural parameter estimation. Replace its observations with your own experimental telemetry when preparing a civil engineering laboratory report submission.

Student: __________________Student ID: __________________Course: __________________Date: __________________Partner: __________________Instructor: __________________

1. Title and aim

Atterberg Consistency Limits & Casagrande Liquid Limit Determination. Determine the Liquid Limit (LL), Plastic Limit (PL), and Plasticity Index (PI) of cohesive soil using the Casagrande mechanical liquid limit cup according to ASTM D4318 / BS 1377-2.

2. Abstract

Six controlled civil engineering laboratory observations were systematically evaluated across operational settings Blow Count N = 15.0 blows to Blow Count N = 40.0 blows for Atterberg Consistency Limits & Casagrande Liquid Limit Determination. Ordinary least-squares regression yielded an empirical Flow Index Parameter I_f of 14.5001 %/log(blow) (difference from theoretical reference = 0.0004%). The empirical telemetry conclusively validates the fundamental civil engineering continuum and constitutive formulation with R² = 1.000000. The investigation demonstrates stable structural and physical behavior, measurement reproducibility, and strict adherence to international ASTM, AASHTO, and ISO standards.

3. Apparatus and fixed settings

4. Theory and graph choice

The consistency and physical behavior of cohesive fine-grained soils depend profoundly on moisture content rather than particle size alone. In 1911, Swedish chemist Albert Atterberg defined four fundamental physical states of soil consistency: solid, semi-solid, plastic, and liquid. In 1932, Arthur Casagrande standardized the mechanical boundary between the plastic and liquid states—the Liquid Limit (LL)—using the mechanical cup apparatus (ASTM D4318). The Liquid Limit is defined as that gravimetric moisture content at which a trapezoidal groove cut through a pat of soil in a brass cup closes over a length of exactly 12.7 mm (0.5 inches) upon receiving exactly 25 standard mechanical blows dropped from a height of 10.0 mm at 2 blows per second onto a hard rubber base. At the liquid limit, all fine-grained soils possess an identical, tiny undrained shear strength of approximately 1.7 to 2.4 kPa. Because achieving exactly 25 blows in a single trial is virtually impossible, tests are performed across four to six trials with blow counts spanning 15 to 40 blows. Plotting moisture content w against log10(N) yields a straight line termed the Flow Curve, whose slope defines the Flow Index I_f = -dw / d(log10 N). The moisture content at N = 25 blows interpolated from the flow curve provides the Liquid Limit LL. Combined with the Plastic Limit (PL, moisture where 3.2 mm soil threads crumble), the Plasticity Index PI = LL - PL classifies soils on Casagrande's Plasticity Chart under the Unified Soil Classification System (USCS). In this laboratory, Casagrande tests are performed to evaluate the Flow Index I_f and establish LL.

w = -14.5000 · log10(N) + 62.0000

The governing physical or constitutive relationship was linearized into the coordinate form y = mx + b. Here, the independent coordinate x represents Common logarithm of blow count log10(N), and the dependent coordinate y represents Moisture content w (%). The gradient m directly determines Flow Index Parameter I_f, while the intercept b accounts for baseline tare values or reference offsets. Linear transformation enables robust parameter estimation via ordinary least squares without non-linear numerical divergence. Plotting transformed observation pairs displays structural stiffness, material strength multipliers, soil shear envelopes, or hydraulic ratings directly as linear slopes.

5. Method

  1. Pass air-dried soil through the 425 μm (No. 40) sieve; take 250 g; calibrate Casagrande cup drop height to exactly 10.0 mm using the thickness gauge on the grooving tool.
  2. Place soil on glass plate; add distilled water gradually, working thoroughly with spatulas for 10 minutes to produce a uniform, smooth plastic paste.
  3. Place a portion of paste into the brass cup above the hinge; spread with spatula to maximum depth of 10 mm; level surface parallel to rubber base.
  4. Draw grooving tool firmly along the cup centerline from hinge toward front in a single continuous stroke, dividing soil pat into two symmetrical halves.
  5. Turn crank at steady rate of 2 blows per second; count blows until soil halves flow together and close across a continuous bottom length of 12.7 mm; record blow count N.
  6. Extract a 15 g sample across the closed groove; weigh immediately; dry in oven at 110 °C to determine w; repeat at varying moisture contents between 15 and 40 blows to establish the Flow Curve.

6. Observations and calculation table

All civil engineering observations use strictly controlled 64-bit IEEE 754 precision buffers. Residuals are computed relative to the ordinary least-squares regression line.

Table 1. Six simulated observations; x and y represent transformed civil engineering metrics.
No.Casagrande Cup Blow Count N (blows)Moisture Content w (%)Common logarithm of blow count log10(N)Moisture content w (%)Fitted yResidual
115.022.73262.708122.732622.7326-0.0000
220.018.56242.995718.562418.56240.0000
325.015.3263.218915.326015.32600.0000
430.012.68263.401212.682612.6826-0.0000
535.010.44813.555310.448110.4482-0.0001
640.08.5113.68898.51108.51100.0000

Download the sample observations (CSV) ↓

7. Worked calculation for one observation

For input Blow Count N = 15.0 blows: Measured Moisture Content w = 22.7326 %. Transformed coordinates: independent x = 2.7081, dependent y = 22.7326.

8. Graph, gradient and final calculation

6.382.5911.002.8915.623.2020.243.5024.873.81Common logarithm of blow count log10(N)Moisture content w (%)

Circular markers represent empirical structural observations. The solid line represents the ordinary least-squares linear fit.

x̄ = 3.2613; ȳ = 14.7104
Σ(x − x̄)² = 0.6672
Σ(x − x̄)(y − ȳ) = -9.6747
m = Σ(x − x̄)(y − ȳ) / Σ(x − x̄)² = -14.50005454
b = ȳ − mx̄ = 62.00020286
y = -14.5001 · x + 62.0002 ⟹ Target Flow Index Parameter I_f = 14.5001 %/log(blow) (theoretical = 14.5000)

9. Uncertainty and comparison

Percentage difference = |estimate − theoretical value| / |theoretical value| × 100 = 0.0004%.

For n = 6 observations, Σresidual² = 6.766e-09; s² = Σresidual²/(n − 2). Gradient standard error = √[s²/Σ(x − x̄)²] = 5.035e-05. Intercept standard error = √[s²(1/n + x̄²/Σ(x − x̄)²)] = 1.651e-04.

Propagating the fit parameters yields a fit standard error of 5.035e-05 %/log(blow), with an ideal coefficient of determination R² = 1.000000.

In civil engineering structural materials testing, geomechanics verification, and hydraulics modeling, empirical uncertainties arise from material microstructural heterogeneity, aggregate packing variations, transducer electronic drift (64-bit IEEE 754 precision digital acquisition), and environmental temperature fluctuations. The ordinary least-squares regression across n = 6 standardized test intervals yields unbiased minimum-variance estimators for both slope and intercept. Because the underlying mechanics—including Hooke's elasticity law, Darcy's porous transport, Bernoulli energy conservation, and Mohr-Coulomb shear strength—adhere strictly to continuum physical principles, residual dispersions remain tightly bounded, yielding an ideal coefficient of determination R² ≥ 0.999999 and confirming the theoretical formulation. Systematic errors (such as machine frame compliance, load cell tare offsets, and temperature drifts) are eliminated using certified calibration standards and differential tare subtraction. Uncertainties in derived moduli, shear strength parameters, and transport coefficients are evaluated via multivariate error propagation.

10. Result and discussion

Flow Index Parameter I_f = 14.5001 %/log(blow)
Theoretical reference value: 14.5000 %/log(blow)

The empirical laboratory observations provide rigorous quantitative verification of Atterberg Consistency Limits & Casagrande Liquid Limit Determination. In civil engineering mechanics of materials, structural analysis, geotechnical engineering, and hydraulics, physical systems are governed by macroscopic equilibrium, compatibility, and constitutive relationships. Across all six observation trials, the empirical slope m = -14.5001 confirms the theoretical model with near-zero residual variance. Furthermore, comparison with established civil engineering benchmarks (Timoshenko & Gere; Terzaghi & Peck; Chow; Neville; and ASTM standards) underscores vital infrastructure design principles including structural safety factors, serviceability deflection limits, and environmental durability. Residual analysis confirms homoscedastic dispersion without systematic non-linear curvature, validating the underlying model assumptions.

11. Precautions and limitations

The civil engineering physical models apply within the specified calibrated operational window (15.0 to 40.0 blows). High-plasticity alluvial clay (CH under USCS). Linearized flow curve relates moisture content w directly to log10(N) with flow index slope -14.5000 %/log(blow) and 0-blow intercept 62.00%. Liquid limit LL at N = 25 blows evaluates as w(25) = -14.50 · log10(25) + 62.00 = -14.50(1.39794) + 62.00 = 41.73%.

12. Conclusion

This laboratory investigation quantitatively verified the mathematical formulation and physical behavior of Atterberg Consistency Limits & Casagrande Liquid Limit Determination. Through rigorous tracking across six observation points, we confirmed an empirical Flow Index Parameter I_f of 14.5001 %/log(blow) matching the theoretical reference 14.5000 %/log(blow) within 0.0004% error. The investigation demonstrates why this civil engineering testing method serves as an indispensable cornerstone in infrastructure design, structural safety assurance, and construction quality control.

In-Depth Technical Supplement & Structural Engineering Derivation

1. Objective & Practical Significance

The primary objective of this geotechnical engineering laboratory investigation is to evaluate the Liquid Limit ($LL$), Plastic Limit ($PL$), and Plasticity Index ($PI$) of cohesive subgrade soil using the Casagrande mechanical cup apparatus according to ASTM D4318 / BS 1377-2 across six blow count levels ($N = 15\text{ to }40\text{ blows}$). By constructing the semi-logarithmic Flow Curve and performing linear regression, we determine the Flow Index $I_f$ and classify the soil on Casagrande's Plasticity Chart under the Unified Soil Classification System (USCS).

2. Governing Transport Equations & Phenomenological Relations

The relationship between moisture content $w$ and mechanical blow count $N$ follows the Casagrande Flow Equation:

\[ w = - I_f \cdot \log_{10}(N) + w_0 \]

where $I_f = 14.5000\%\text{/log(blow)}$ is the Flow Index and $w_0 = 62.0000\%$ is the intercept. The Liquid Limit is defined as the moisture content at exactly $N = 25\text{ blows}$:

\[ LL = w(N=25) \]

3. Experimental Apparatus & Instrumentation Specification

Testing utilized an ASTM D4318 motorized Casagrande liquid limit device comprising a brass cup ($M = 200.0 \pm 2.0\text{ g}$) dropping $10.00 \pm 0.05\text{ mm}$ onto a calibrated hard rubber base (Shore D hardness $60 \pm 5$). Grooving was executed with an ASTM flat grooving tool ($2.0\text{ mm}$ cutting tip, $11.0\text{ mm}$ top width). Moisture determination utilized a digital top-loading analytical balance ($200.0\text{ g}$ capacity, precision $\pm 0.01\text{ g}$) and a forced-convection drying oven ($110 \pm 5^\circ\text{C}$). The test soil was the fraction passing the $425\,\mu\text{m}$ (No. 40) sieve.

4. Standard Operating Procedure & Measurement Protocols

The cup drop height was verified using the $10.0\text{ mm}$ gauge block. A $250\text{ g}$ soil sample was mixed with distilled water into a smooth paste. Portions were placed in the cup, leveled to $10\text{ mm}$ depth, and grooved along the centerline. The crank was rotated at $2\text{ blows/s}$ until the groove closed over a length of $12.7\text{ mm}$. The blow count $N$ was logged, a $15\text{ g}$ moisture sample extracted across the closure zone, and dried for 24 hours. The test was repeated across six moisture contents yielding blow counts between 15 and 40.

5. Safety Analysis, Hazard Mitigation & Personal Protection

Repetitive manual cranking presents ergonomic strain; motorized drives were operated with guards. Oven drying handles presented thermal burn risks; insulated gloves were used when transferring tare containers.

6. Raw Experimental Observations & Systematic Data Records

Simulated demonstration data. The following systematic observations were recorded across the Casagrande flow curve test series:

TrialBlow Count N (blows)log10(N)Tare Container No.Wet Soil + Tare (g)Dry Soil + Tare (g)Moisture Content w (%)
115.01.1761C-138.4529.5844.95
220.01.3010C-239.1230.3443.14
325.01.3979C-341.2032.2841.73
430.01.4771C-437.8029.8940.58
535.01.5441C-540.1532.0539.61
640.01.6021C-638.9031.2538.77

Plastic Limit Testing: Hand-rolled $3.2\text{ mm}$ threads crumbled at an average moisture content of $PL = 21.20\%$.

7. Quantitative Mathematical Analysis & Regression Models

Linear regression of moisture content $w$ versus common logarithm of blow count $x = \log_{10}(N)$ yields:

\[ w = -14.50000 \cdot \log_{10}(N) + 62.00000 \]

with an extraordinary coefficient of determination $R^2 = 1.000000$. The absolute experimental Flow Index $I_f = 14.5000\%\text{/log(blow)}$ matches the reference design benchmark ($14.5000$) with zero relative deviation ($0.00\%$). Calculating the Liquid Limit at $N = 25\text{ blows}$:

\[ LL = -14.50000 \times \log_{10}(25) + 62.00000 = -14.50000(1.39794) + 62.00000 = 41.73\% \]

Evaluating Plasticity Index:

\[ PI = LL - PL = 41.73\% - 21.20\% = 20.53\% \]

8. Rigorous Error Analysis & Uncertainty Propagation

Uncertainties include balance precision $\delta m = \pm 0.01\text{ g}$, blow count visual detection $\delta N = \pm 1\text{ blow}$, and drop height calibration $\delta h = \pm 0.1\text{ mm}$. Propagating into $LL$:

\[ \delta LL = \sqrt{ \left( \frac{I_f}{N \ln 10} \delta N \right)^2 + \delta w^2 } = \pm 0.28\% \]

The reported Liquid Limit is $LL = 41.73 \pm 0.28\%$.

9. Engineering Discussion & Phenomenological Interpretation

On Casagrande's Plasticity Chart, plotting $PI = 20.53\%$ against $LL = 41.73\%$ locates the soil above the empirical A-Line ($PI_{A-Line} = 0.73(LL - 20) = 0.73(41.73 - 20) = 15.86\%$). Because $LL < 50\%$ and $PI > 7$, the soil classifies unambiguously as a **CL (Inorganic Clay of Medium Plasticity)** under the USCS system and **A-6** under the AASHTO system.

10. Geotechnical Swell & Settlement Engineering Implications

Soil classification as CL with $LL = 41.7\%$ indicates moderate shrink-swell potential and moderate compressibility. Empirical correlations with Liquid Limit confirm: Compression Index $C_c \approx 0.009(LL - 10) = 0.009(31.7) = 0.285$, perfectly validating the oedometer consolidation test results obtained in Laboratory 22.

11. Self-Assessment Conceptual Questions & Model Answers

Q1: Why does testing soil that has been oven-dried before Atterberg testing produce erroneous results?
A1: Oven drying at $110^\circ\text{C}$ causes irreversible collapse of clay mineral lattices and drives off structural interlayer water, agglomerating fine platelets into permanent silt-sized clusters that artificially lower both Liquid Limit and Plasticity Index by $20\text{ to }40\%$.

Q2: What is the Activity of clay, and how is it related to mineralogy?
A2: Activity is defined as $A_c = PI / (\% \text{ clay fraction } < 2\,\mu\text{m})$; kaolinite has low activity ($A_c < 0.5$), illite moderate ($0.75\text{ to }1.25$), and sodium bentonite (montmorillonite) extreme activity ($A_c > 4.0$), dictating massive volumetric swelling.

12. Concluding Summary & Verified Engineering Metric

The Casagrande liquid limit investigation accurately established the consistency boundaries and plasticity characteristics of the cohesive soil. The verified Flow Index $I_f = 14.5000\%\text{/log(blow)}$ ($R^2 = 1.000000$), Liquid Limit $LL = 41.73\%$, and Plasticity Index $PI = 20.53\%$ provide an authoritative basis for soil classification and foundation engineering.