Bernoulli's Theorem & Venturi Workstation Frame
Provides rigid calibrated mounting, regulated excitation, and alignment for static vs dynamic head, continuity equation & boundary layer friction recovery.
Demonstrate the conservation of total mechanical energy along a converging-diverging venturi conduit, measuring piezometric and total pressure heads at multiple cross sections. Explore interactive mechanical simulation, stress-strain telemetry, and continuum mechanics.
Ready to sample with Squared Flow Rate = 4.5 m⁶/s² ×10⁻⁶.
Adjust Squared Flow Rate, then execute mechanical acquisition.
Mechanical measurements are captured using precision transducers and 64-bit IEEE 754 floating-point logging. Residuals reflect ordinary least-squares regression across successive observations. Continuous data structures support comprehensive stress, thermal, and dynamical evaluation.
All structural components assume isotropic linear elastic behavior within small-strain deformation limits. Fluid flow fields comply with Navier-Stokes continuum conservation under negligible thermal dissipation.
Provides rigid calibrated mounting, regulated excitation, and alignment for static vs dynamic head, continuity equation & boundary layer friction recovery.
Measures applied axial, transverse, or shear mechanical forces with ±0.05% baseline accuracy.
Quantifies minute mechanical displacements, elastic deflections, and strain elongations with 0.001 mm resolution.
Samples strain gauge bridge signals, load cell voltages, temperature probes, and pressure transducers at 1 kHz.
Supplies verified physical calibration benchmarks to establish standardized squared flow rate setpoints.
Eliminates thermal EMF drift, lead wire resistance errors, and ambient mechanical vibration noise.
Demonstrate the conservation of total mechanical energy along a converging-diverging venturi conduit, measuring piezometric and total pressure heads at multiple cross sections. Standardized parameter settings: 1.0, 2.25, 4.0, 5.76, 7.29, 9.0 m⁶/s² ×10⁻⁶.
Points are your recorded observations. The solid regression line validates Bernoulli's Theorem & Venturi mathematical scaling.
| # | Squared Volumetric Flow Rate Q² (m⁶/s² ×10⁻⁶) | Differential Piezometric Head Loss Δh (mm) | Squared flow rate Q² (m⁶/s² ×10⁻⁶) | Differential head loss Δh (mm) |
|---|
No readings yet. Execute a mechanical trial and record it.
The experimental protocol directly measures Differential Piezometric Head Loss Δh as a function of the manipulated Squared Flow Rate.
Linear regression across calibrated observations confirms the governing equation Δh = 2500.0 · Q² with R² > 0.999.
The experimental slope and intercept directly yield Venturi Dynamic Pressure Gradient with a theoretical reference value of 2500.0 mm/(m⁶/s² ×10⁻⁶).
LVDT inductive transducers and bonded piezoresistive foil strain gauges provide sub-micron resolution for precision structural deflection and strain measurement.
Demonstrate the conservation of total mechanical energy along a converging-diverging venturi conduit, measuring piezometric and total pressure heads at multiple cross sections.
Mechanical engineering principles build upon continuum mechanics, thermodynamics, fluid dynamics, and rigid-body kinetics.